What is product load in refrigeration system?

What is product load in refrigeration system?

The total product load is the sum of the individual calculations for the sensible heat above freezing, the latent heat of freezing, and the sensible heat below freezing. From the foregoing example, if 1,000 pounds of veal were to be cooled from 42°F to 0°F, the total would be: Sensible Heat above freezing 9,230 BTU.

How do you calculate cooling load?

Calculating a Home’s Cooling Load

  1. Determine the dimensions of the room or home that needs cooling. For a room, you can do this with a measuring tape.
  2. For a room, multiply its length by its width to get the square footage.
  3. Multiply the square footage by 20. This is the measure of the BTU cooling load of the space.

How is CLTD calculated?

Equations

  1. For heat gain through walls, doors, roofs, and windows (only window conduction) Q = U*A*CLTD.
  2. For heat gains due to people, equipment (hooded and unhooded), and lighting. Q = Q*CLF.
  3. For solar heat gains through windows and glazed surfaces. Q = A*SC*SCL.
  4. Data tables.

How is HVAC load calculated?

Calculate the HVAC load (House surface in square feet) x (height of the ceiling) (Number of occupants) x 100 BTU. (Number of exterior doors) x 1,000 BTU. (Number of windows) x 1,000 BTU.

How do you calculate product load?

Product load – Product exchange °C. Q = m x Cp x (Temp enter – Temp store) / 3600. 3600 = convert from kJ to kWh.

How do you calculate tons of refrigeration capacity?

Some commercial and industrial refrigeration systems are rated in Tons of Refrigeration (TR, tons). A ton is the amount of heat removed by an air conditioning system that would melt 1 ton (2000 lbs.)…Converting between Btu/h and Tons of Refrigeration.

Btu/h Refrigeration Ton kW
48000 4 14.1
54000 4 1/2 15.8
60000 5 17.6

What is a load calculation?

A load calculation is a method of determining the heat gain and loss of a building. Over the years many approaches have been taken. Most contractors, however, have historically referenced the Air Conditioning Contractors of America (ACCA) Manuel J as a basis for residential calculations.

What is peak cooling load?

In the hottest time of summer, the peak cooling load is the amount of heat that must be removed in an hour to maintain a comfortable room temperature.

What is cooling load in HVAC?

The cooling load is the amount of heat energy that would need to be removed from a space (cooling) to maintain the temperature in an acceptable range. The heating and cooling loads, or “thermal loads”, take into account: the dwelling’s construction and insulation; including floors, walls, ceilings and roof; and.

How is thermal load calculated?

Heat load (BTU) = Length (m) x Width (m) x Height (m) x 141. So, for a room measuring 5m x 4m x 3m = 60 > x 141 = 8,460 BTU. (For measurements in feet, the formula becomes: Heat load (BTU) = Length (m) x Width (m) x Height (m) x 4)

What is Manual J load calculation?

But, what is a Manual J load calculation? Simply stated a Manual J load calculation factors in the different characteristics of your home (such as square footage, position of your walls, building materials, etc.) to determine how much heating or cooling capacity your home needs.

How do you calculate kW per TR?

Electric motor driven chillers are rated in kilowatts per ton cooling.

  1. kW/ton = 12 / EER.
  2. kW/ton = 12 / (COP x 3.412)
  3. COP = EER / 3.412.
  4. COP = 12 / (kW/ton) / 3.412.
  5. EER = 12 / (kW/ton)
  6. EER = COP x 3.412.